Diagnostic Tool

Click on a section of the dialog for more information:

Xenetech Graphic Workstation does NOT have to be running in order to use this utility

Using This Utility

  1. Turn on the MPU.

  2. Be sure that all cables are connected.  If you are unsure then please check the Xenetech Hardware manual for reference.

  3. Press the reset button on the back of the pendant.

  4. Place the "Character/Line/Plate" switch to the Line position.

  5. Place the "Cutter" Switch to the up position.

  6. Open the diagnostic tool.

  7. Click on the Start button to begin testing.

  8. When the diagnostic tool initializes, if the spindle motor is in the auto position, the tool will verify that the spindle motor is working by turning it on.  Place the Spindle motor switch to the off position to stop the test.

  9. Press the Stop button to end the testing.  Press the Exit button to exit the utility.